1 - 4 de 4
1.
Radiat Oncol ; 17(1): 39, 2022 Feb 22.
Article En | MEDLINE | ID: mdl-35193627

BACKGROUND: Some patients have noted a foul odor during radiation therapy sessions, but the cause of the odor remains unknown. Since we suspected that this phenomenon is due to ozone generated by ionizing radiation, this experimental study measured ozone concentrations in the treatment room and in a coiled polyvinyl chloride (PVC) tube placed within the radiation field. METHODS: We measured ozone concentrations using an ultraviolet absorption method and an ozone monitor. A PVC tube (inner diameter 7 mm, outer diameter 10 mm) was used to mimic the environment of the nasal cavity. The tube (790 cm) was coiled and set between two 4-cm-thick (for X-rays) or 2-cm-thick (for electron beams) water-equivalent solid phantoms. The sampling tube of the ozone monitor was inserted into the PVC tube, and the joint was sealed to prevent environmental air contamination. To measure ozone concentrations in the atmosphere, the sampling tube supplied with the unit was used. A linac was used on a full-sized treatment field (40 cm × 40 cm at a source-to-axis distance of 100 cm). The effect of an electron beam on ozone concentrations was also evaluated with a full-sized treatment field (40 cm × 40 cm at a source-to-surface distance of 100 cm). RESULTS: Ozone levels in the treatment room were undetectable before the start of daily treatment but reached 0.008 parts per million (ppm) or more at 1 h after the start of treatment. Concentrations then remained nearly constant at 0.010-0.015 ppm throughout the day. The maximum ozone concentration in the PVC tube was only 0.006 ppm, even when it was irradiated at 2400 monitor units/min. Depending on the X-ray dose rate, the concentration increased to a maximum of 0.010 ppm with oxygen flowing into the other end of the tube at 1.5 L/min. Ozone concentrations in the PVC tube did not differ significantly between X-ray and electron-beam irradiation. CONCLUSIONS: Only traces of ozone were found in the PVC tube that was used to mimic the nasal passages during radiation, these concentrations were too low for human perception. However, ozone concentrations did reach potentially detectable levels in the treatment room.


Ozone/analysis , Particle Accelerators , Radiotherapy , Phantoms, Imaging
2.
Phys Med ; 41: 141-146, 2017 Sep.
Article En | MEDLINE | ID: mdl-28869137

Proton radiography is a novel imaging modality that allows direct measurement of the proton energy loss in various tissues. Currently, due to the conversion of so-called Hounsfield units from X-ray Computed Tomography (CT) into relative proton stopping powers (RPSP), the uncertainties of RPSP are 3-5% or higher, which need to be minimized down to 1% to make the proton treatment plans more accurate. In this work, we simulated a proton radiography system, with position-sensitive detectors (PSDs) and a residual energy detector (RED). The simulations were built using Geant4, a Monte Carlo simulation toolkit. A phantom, consisting of several materials was placed between the PSDs of various Water Equivalent Thicknesses (WET), corresponding to an ideal detector, a gaseous detector, silicon and plastic scintillator detectors. The energy loss radiograph and the scattering angle distributions of the protons were studied for proton beam energies of 150MeV, 190MeV and 230MeV. To improve the image quality deteriorated by the multiple Coulomb scattering (MCS), protons with small angles were selected. Two ways of calculating a scattering angle were considered using the proton's direction and position. A scattering angle cut of 8.7mrad was applied giving an optimal balance between quality and efficiency of the radiographic image. For the three proton beam energies, the number of protons used in image reconstruction with the direction method was half the number of protons kept using the position method.


Image Processing, Computer-Assisted , Protons , Radiography/instrumentation , Monte Carlo Method , Phantoms, Imaging , Tomography, X-Ray Computed
3.
Sci Rep ; 6: 18808, 2016 Jan 04.
Article En | MEDLINE | ID: mdl-26725651

The detrimental influence of oxygen on the performance and reliability of V/III nitride based devices is well known. However, the influence of oxygen on the nature of the incorporation of other co-dopants, such as rare earth ions, has been largely overlooked in GaN. Here, we report the first comprehensive study of the critical role that oxygen has on Eu in GaN, as well as atomic scale observation of diffusion and local concentration of both atoms in the crystal lattice. We find that oxygen plays an integral role in the location, stability, and local defect structure around the Eu ions that were doped into the GaN host. Although the availability of oxygen is essential for these properties, it renders the material incompatible with GaN-based devices. However, the utilization of the normally occurring oxygen in GaN is promoted through structural manipulation, reducing its concentration by 2 orders of magnitude, while maintaining both the material quality and the favorable optical properties of the Eu ions. These findings open the way for full integration of RE dopants for optoelectronic functionalities in the existing GaN platform.

4.
Phys Rev Lett ; 115(17): 172503, 2015 Oct 23.
Article En | MEDLINE | ID: mdl-26551108

Absolute cross sections for isotopically identified products formed in multinucleon transfer in the (136)Xe+(198)Pt system at ∼8 MeV/nucleon are reported. The isotopic distributions obtained using a large acceptance spectrometer demonstrated the production of the "hard-to-reach" neutron-rich isotopes for Z<78 around the N=126 shell closure far from stability. The main contribution to the formation of these exotic nuclei is shown to arise in collisions with a small kinetic energy dissipation. The present experimental finding corroborates for the first time recent predictions that multinucleon transfer reactions would be the optimum method to populate and characterize neutron-rich isotopes around N=126 which are crucial for understanding both astrophysically relevant processes and the evolution of "magic" numbers far from stability.

...